Graphtec GL7000 Data acquisition  
 
 
 
Graphtec GL7000 Data acquisition
Graphtec GL7000 Data acquisition  
Product ID :
GL-7000
Price :
-
Updated :
25/06/2020
Quantity :
1 piece
Status :
FirstHand
Brand :
Graphtec
Model:
GL7000
Link :
-
Manual/Product reference :
-
  Tell a Friend 
Detail

Graphtec Data Platform GL7000 

 

 

The module can be expanded to accommodate a wide variety of measurements

It can measure the desired signal according to the needs and can expand into other applications adding different amplifier modules.

 

Modular system allows expansion of measurements and channels

 A wide variety of measurements can be supported by the amplifier module

Measurements for different applications can be added to the amplifier module. It is also possible to mix measurements by adding different types of modules.

The Voltage module, Voltage/Temperature module, High Speed Voltage module and Logic/Pulse models are available. The other modules will be released sequentially starting in the autumn of 2012.

Amplifier can be attached to up to 10 modules

Up to 10 amplifier modules can be attached for multi-channel measurements, with up to 112 channels on one GL7000.

Maintains sampling speed even if the number of amplifier modules are increased

Voltage* and Volt/Temp amplifier can maintain high-speed and multi-channel measurements without dropping the sampling speed, even if the number of modules are increased.

Require more channels

Multi-channel measurement is possible to 1120 channels using the PC

Up to 10 units of the GL7000 can be connected to 1 PC through LAN or USB and controlled using the software.

 

Up to 5 units of the GL7000 can be fully synchronized using the sync. Cable

The start/stop trigger, and sampling can be synchronized in the GL7000 when they are connected by a sync cable. The master and slave units are automatically identified.

 

Suitable for a variety of measurements by different type of amplifier module

Suitable for a variety of measurements due to flexible module combinations

Four type of modules are available.

Voltage Module

The output of various sensors such as displacement, pressure, wind speed, etc.
Cell voltage of the battery.

Voltage/
Temperature Module

Measuring temperature and voltage simultaneously. For environmental tests, etc.

High Speed Voltage Module

Measurement of parameters in the inverter system, vibration test, drop test, etc.

Logic/Pulse Module

Timing of system control signal, encoder output, rotational 

Modules will be released sequentially starting in the autumn of 2012.

High Voltage Module

Measurement of the high voltage in the power line of equipment, Electric or Hybrid Vehicle testing, etc.

Charge Module

Measuring the output of sensor using the Piezoelectric device. Measurement of the vibration, acceleration, pressure, force, etc.

Voltage Output Module

An analog voltage corresponding to the captured data is output. Simulation testing by the actual measured data, the    vibration test, etc.

Power Measurement Module

Measuring the voltage, current and power. Measurement of the power line of the device, etc

DC Strain Module

Measuring the output of sensor using the strain gauge. Measurement of the load, displacement, vibration, acceleration, torque, pressure, etc.

Multiple storages for reliable long term measurement

Supports four destinations to save the captured data according to the conditions of the measurement

1. Built-in RAM

The RAM to save 2 million samples is built into each amplifier module. The data capture duration does not decrease with increasing numbers of channels because the built-in RAM for each amplifier module is used.

2. Built-in Flash memory

The 2GB of Flash memory is built into the main module. The captured data can be saved directly to the built-in Flash memory when the sampling is not faster than 1ms (sampling speed: 1 k Samples/s). Saved data is retained even when power is turned off because flash memory is used.

3. SD memory card

SD card slot (supports SDHC, up to 32GB) is standard on the main module. The captured data can be saved directly to the SD memory card when the sampling is not faster than 1ms (sampling speed: 1 k Samples/s). It supports hot-swap, so the SD memory card can be replaced during measurement without data loss.* The captured data can be transferred easily to the PC in offline condition.

* The hot-swap is possible when the sampling is slower than 100ms.

4. SSD module (64GB)

Allows large amounts of data to be quickly saved when the optional SSD module is attached. The captured data can be saved directly to the SSD when the sampling is not faster than 1µs (sampling speed: 1 M Samples/s).* It has a high vibration resistance and saved data is also retained even when power is turned off.

* The number of modules are limited.

 

Easy operation with large display and touch panel

Improved ease-of-use with the high-definition display and touch panel

The touch panel makes setting the conditions intuitive, and it can also be operated using the cursor keys similar to the GL series.

 

Large easy-to-read 5.7-inch high-definition LCD monitor

Utilises a bright clear 5.7 inch wide TFT color LCD monitor (VGA: 640 x 480 dots). Makes it easy to read data in wave form or digital form and to check measurement parameter settings.

 

 

Support stand-alone operation and embedding into a system

The detachable display module allows both stand-alone and embedded system configurations

Measurement settings and signal measurement can both be done without a PC by attaching the display module. The display module can be moved to different locations for remote operation by connecting it to the main module with a LAN cable*, it also can be embedded into the system. The module can still be operated by the PC even when the display module is connected.

* Up to 10m using CAT5 LAN cable (straight connection)

 

 

High performance application software

Software for high performance and easy operation

The GL7000 can be controlled by the GL-Connection software that is included. The software has convenient functions such as saving data to the PC, replaying captured data, and converting data form. It is an integrated application software for the GL series, the GL900, GL820 and GL220 can also be connected.*

* The version for supporting other GL series will be available in December 2012.

Various measurement screens

The measurement signal can be displayed as various types of screens by the unit, the module or the specific channels that are specified in the group function. It can also be displayed as a combination of the capturing data and captured data, the Y-T format and the X-Y format, simultaneously. Up to 112 channels can be displayed in each window.*

* In case of using dual screen, total 244 channels can be displayed.

 

 

Multi-window function, measured waveform can be displayed in various forms using multiple windows

 

Useful functions

For real time and the post processing.

  • Statistical Calculation
    The maximum, minimum, peak, and average values are displayed while capturing data. The value between the cursors of the maximum, minimum, peak, average, and RMS will be displayed when replaying captured data.
  • File operation
    The data can be converted to the CSV format for a specified period, all data, or multiple files. A file can also be created by compressing or consolidating multiple files.